Main parts material and range of applicable of electric gate valve
Valve Body | WCB | WC6/WC9 |
Bonnet | WCB | 12Cr1MoV |
Valve Rod | 38CrMoAlA | 25Cr2MoV |
Flashboard | 25/WCB | WC6/WC9 |
Universal Joint | 38CrMoAlA | 38CrMoAlA |
Bolt | B7 | 25Cr2MoV |
Applicable Medium | Water, Gas, Oil, etc. | Water, Gas, Oil, etc. |
Maximum Operating Temperature | 425℃ | 550/590℃ |
Classification of operating temperature
(1) Ultralow temperature valve: apply to the valve which medium operating temperature t<-100℃.
(2) Low temperature valve: apply to the valve which medium operating temperature -100℃≤t≤-40℃.
(3) Normal temperature valve: apply to the valve which medium operating temperature -40℃≤t≤120℃.
(4) Intermediate temperature valve: apply to the valve which medium operating temperature 120℃.
(5) High temperature valve: apply to the valve which medium operating temperature t>450℃.
The matching actuator parameters are as follows:
Z series multi-turn electric actuator connection flange dimensions
Type | Torque type(JB2920) | Thrust type( GB/T12222-2005} | |||||||||||||||
Parameter | Base code | D | D1 | D2 | d2 | d1 | h | h1 | f | n-d | Flange Code | D | D1 | D2 | D1 | n-d | f |
Z10-15 | 2 | 145 | 120 | 90 | 45 | 30 | 8 | 2 | 5 | 4-M10 | F10 | 125 | 102 | 70 | Tr28 | 4-M10 | 3 |
2I | 115 | 95 | 75 | 39 | 26 | 6 | 2 | 4 | 4-M8 | ||||||||
Z20-30 | 3 | 185 | 160 | 125 | 59 | 42 | 10 | 2 | 5 | 4-M12 | F14 | 175 | 140 | 100 | Tr36 | 4-M16 | 4 |
3I | 145 | 120 | 90 | 45 | 30 | 8 | 2 | 5 | 4-M10 | ||||||||
Z45-60 | 4 | 225 | 195 | 150 | 72 | 50 | 12 | 2 | 5 | 4-M16 | F16 | 210 | 165 | 130 | Tr44 | 4-M20 | 5 |
Z90-120 | 5 | 275 | 235 | 180 | 82 | 62 | 14 | 2 | 5 | 4-M20 | F25 | 300 | 254 | 200 | Tr60 | 4-M16 | 5 |
5I | 230 | 195 | 150 | 72 | 50 | 12 | 2 | 5 | 4-M16 | ||||||||
Z180-250 | 7 | 330 | 285 | 220 | 98 | 72 | 16 | 3 | 6 | 4-Φ27 | F30 | 350 | 298 | 230 | Tr70 | 4-M20 | 5 |
Z350 | 8 | 380 | 340 | 280 | 118 | 82 | 20 | 3 | 6 | 4-Φ22 | F35 | 415 | 356 | 260 | Tr80 | 4-M30 | 5 |
Remarks
1.The I in the frame number indicates the power station type;
2. The diameter of the trapezoidal thread in the thrust type is the maximum selected diameter.
3. The position of the mounting hole of the connecting plate is symmetrically distributed with the axis of the motor.
Zseries Multi-turn Electric Actuator Outline
Type Parameter | L | L1 | H | H1 | F1 On-off type | F2 Intelligent type | ΦD |
Z5-15 | 382 | 228 | 233 | 87 | 150 | 203 | 300 |
Z20-30 | 435 | 278 | 248 | 90 | 157 | 210 | 350 |
Z45-60 | 640 | 410 | 325 | 116 | 268 | 380 | 420 |
Z90-120 | 830 | 540 | 450 | 200 | 685 | 510 | 550 |
Z180-250 | 870 | 565 | 600 | 250 | 740 | 535 | 320 |
Z350-500 | 1170 | 770 | 710 | 280 | 840 | 450 |