Z series multi-turn Technical Parameters
Model | Output | Nominal | Motor | Rated current | Manual Speed | Max | Reference |
| r/min | NM | KW | A | I | MM | KG |
Z5 | 18 | 50 | 0.12 | 0.6 | 1:1 | 28 | 20 |
Z10 | 18 | 100 | 0.18 | 1 | 1:1 | 28 | 20 |
Z15 | 18 | 150 | 0.25 | 1.2 | 1:1 | 28 | 20 |
Z20 | 18 | 200 | 0.37 | 1.38 | 1:1 | 40 | 26 |
Z30 | 18 | 300 | 0.55 | 2.7 | 1:1 | 40 | 26 |
Z45 | 24 | 450 | 1.1 | 4 | 1:1 | 48 | 110 |
Z60 | 24 | 600 | 1.5 | 4.12 | 1:1 | 48 | 120 |
Z90 | 24 | 900 | 2.2 | 5.25 | 1:1 | 60 | 139 |
Z120 | 24 | 1200 | 3 | 7.9 | 1:1 | 60 | 142 |
Z180 | 18 | 1800 | 4 | 8.87 | 22.5:1 | 70 | 250 |
Z250 | 18 | 2500 | 5.5 | 12.05 | 22.5:1 | 70 | 255 |
Z350 | 18 | 3500 | 7.5 | 15.6 | 20:1 | 80 | 330 |
Z500 | 18 | 5000 | 10 | 20.5 | 20:1 | 80 | 350 |
Remarks: The above is a regular order, if you have special needs, you can specify when ordering.
Structure Size
Z series multi-turn electric actuator connection flange dimensions
Type | Torque type(JB2920) | Thrust type( GB/T12222-2005} | |||||||||||||||
Parameter | Base code | D | D1 | D2 | d2 | d1 | h | h1 | f | n-d | Flange Code | D | D1 | D2 | D1 | n-d | f |
Z10-15 | 2 | 145 | 120 | 90 | 45 | 30 | 8 | 2 | 5 | 4-M10 | F10 | 125 | 102 | 70 | Tr28 | 4-M10 | 3 |
2I | 115 | 95 | 75 | 39 | 26 | 6 | 2 | 4 | 4-M8 | ||||||||
Z20-30 | 3 | 185 | 160 | 125 | 59 | 42 | 10 | 2 | 5 | 4-M12 | F14 | 175 | 140 | 100 | Tr36 | 4-M16 | 4 |
3I | 145 | 120 | 90 | 45 | 30 | 8 | 2 | 5 | 4-M10 | ||||||||
Z45-60 | 4 | 225 | 195 | 150 | 72 | 50 | 12 | 2 | 5 | 4-M16 | F16 | 210 | 165 | 130 | Tr44 | 4-M20 | 5 |
Z90-120 | 5 | 275 | 235 | 180 | 82 | 62 | 14 | 2 | 5 | 4-M20 | F25 | 300 | 254 | 200 | Tr60 | 4-M16 | 5 |
5I | 230 | 195 | 150 | 72 | 50 | 12 | 2 | 5 | 4-M16 | ||||||||
Z180-250 | 7 | 330 | 285 | 220 | 98 | 72 | 16 | 3 | 6 | 4-Φ27 | F30 | 350 | 298 | 230 | Tr70 | 4-M20 | 5 |
Z350 | 8 | 380 | 340 | 280 | 118 | 82 | 20 | 3 | 6 | 4-Φ22 | F35 | 415 | 356 | 260 | Tr80 | 4-M30 | 5 |
Remarks:
1. The I in the frame number indicates the power station type.
2. The diameter of the trapezoidal thread in the thrust type is the maximum selected diameter.
3. The position of the mounting hole of the connecting plate is symmetrically distributed with the axis of the motor.
Z series Multi-turn Electric Actuator Outline
Type | L | L1 | H | H1 | F1 | F2 | ΦD |
Z5-15 | 382 | 228 | 233 | 87 | 150 | 203 | 300 |
Z20-30 | 435 | 278 | 248 | 90 | 157 | 210 | 350 |
Z45-60 | 640 | 410 | 325 | 116 | 268 | 380 | 420 |
Z90-120 | 830 | 540 | 450 | 200 | 685 | 510 | 550 |
Z180-250 | 870 | 565 | 600 | 250 | 740 | 535 | 320 |
Z350-500 | 1170 | 770 | 710 | 280 | 840 | 450 |