Item Body base No. | Type | Output torque (N.m) | Output rotational speed (r/min) | Parameters of motor (Three-phase) | 90°Full travel time (S) | Weight of basic model (kg) | |
Reference power (KW) | Rated power (A) | ||||||
SLP30 | SLP5-l | 50 | 1.0 | 0.04 | 0.26 | 15.0 | 23 |
SLP10-1 | 100 | 0.06 | 0.40 | ||||
SLP15-1 | 150 | 0.09 | 0.60 | ||||
SLP20-1 | 200 | 0.09 | 0.60 | ||||
SLP30-1 | 300 | 0.12 | 0.70 | ||||
SLP90 | SLP40-0.5 | 400 | 0.50 | 0.09 | 0.60 | 30.0 | 42 |
SLP40-1 | 1.0 | 0.18 | 0.95 | 15.0 | |||
SLP60-0.5 | 600 | 0.50 | 0.12 | 0.70 | 30.0 | ||
SLP60-1 | 1.0 | 0.18 | 0.95 | 15.0 | |||
SLP90-0.5 | 900 | 0.50 | 0.18 | 0.95 | 30.0 | ||
SLP90-1 | 1.0 | 0.25 | 1.30 | 15.0 | 56 | ||
SLP120 | SLP100-0.5 | 1000 | 0.50 | 0.25 | 1.30 | 30.0 | |
SLP100-1 | 1.0 | 0.37 | 1.60 | 15.0 | |||
SLP120-0.5 | 1200 | 0.50 | 0.25 | 1.30 | 30.0 | ||
SLP120-1 | 1.0 | 0.37 | 1.60 | 15.0 | |||
SLP300 | SLP200-0.5 | 2000 | 0.50 | 0.37 | 1.60 | 30.0 | 70 |
SLP200-1 | 1.0 | 0.55 | 1.40 | 15.0 | |||
SLP250-0.5 | 2500 | 0.50 | 0.37 | 1.60 | 30.0 | ||
SLP250-1 | 1.0 | 0.55 | 2.40 | 15.0 | |||
SLP300-0.5 | 3000 | 0.50 | 0.55 | 1.40 | 30.0 | ||
SLP800 | SLP400-0.25 | 4000 | 0.25 | 0.37 | 1.60 | 60.0 | 145 |
SLP400-0.5 | 0.50 | 0.55 | 2.40 | 30.0 | |||
SLP600-0.25 | 6000 | 0.25 | 0.55 | 2.40 | 60.0 | ||
SLP600-0.5 | 0.50 | 1.10 | 3.40 | 30.0 | |||
SLP800-0.25 | 8000 | 0.25 | 1.10 | 3.40 | 60.0 | ||
SLP1600 | SLP800-0.5 | 10000 | 0.50 | 1.50 | 4.50 | 30.0 | 220 |
SLP1000-0.3 | 12000 | 0.30 | 1.50 | 4.50 | 50.0 | ||
SLP1200-0.3 | 0.30 | 1.50 | 4.50 | 50.0 | |||
SLP1600-0.2 | 16000 | 0.20 | 1.50 | 4.50 | 75.0 |
Notes: This sheet provides the related parameters of 380V three-phase motor only.The guaranty value of the ratio between the motor blocking current and the rated current is 7 an the rated voltage. The allowance is 20% of the guaranty value. When the operating product is single-phase, the parameters to the product documents and the shipping mark.
SLP30, SLP90 and SLP30L,SLP90L Configuration diagram (Basic model and general local model)
SLP30, SLP90 and SLP30L, SLP90L Configuration dimensions sheet
A | B | C | D | E | F | G | H | I | J | |
SLP30 | 55 | 270 (MAX) | 188 | Ф200 | Ф180 | Ф125 | 65 | 260 | 84 | ≈80 |
SLP30L | ||||||||||
SLP90 | 75 | 35(MAX) | 205 | Ф250 | Ф202 | Ф175 | 87 | 287 | 98.5 | ≈110 |
SLP90L | ||||||||||
K | L | M | N | O | P | Q | R | S | T | |
SLP30 | 65 | 65 | Ф102 | Ф116 | ≈138 | 65 | ||||
SLP30L | 145 | 215 | ||||||||
SLP90 | 87 | 87 | Ф124 | Ф130 | ≈160 | 85 | ||||
SLP90L | 160 | 230 |
SLP120~SLP1600 and SLP120L~SLPl600L Configuration diagram (Basic model and general local model)
SLP120~SLP1600 and SLP120L~SLP 1600L Configuration dimensions sheet
A | B | C | D | E | F | G | H | I | J | |
SLP120 | 103 | 360(MAX) | 175 | Ф250 | Ф202 | Ф235 | 115 | 325 | 130 | 160 |
SLP120L | ||||||||||
SLP300 | 117 | 370(MAX) | 200 | Ф300 | Ф202 | Ф270 | 134 | 352 | 157 | 175 |
SLP300L | ||||||||||
SLP800 | 134 | 460 (MAX) | 265 | Ф600 | Ф220 | Ф310 | 162/181 | 410/429 | 206/225 | 200 |
SLP800L | ||||||||||
SLP1600 | 134 | 480(MAX) | 265 | Ф600 | Ф220 | Ф440 | 230 | 530 | 293 | 270 |
SLP1600L | ||||||||||
K | L | M | N | O | P | Q | R | S | T | |
SLP120 | 66 | 140 | 25 | 82 | Ф124 | Ф130 | ≈210 | 85 | ||
SLP120L | 205 | 275 | ||||||||
SLP300 | 70 | 117 | 25 | 106 | Ф124 | Ф130 | ≈230 | 120 | ||
SLP300L | 215 | 285 | ||||||||
SLP800 | 85 | 225/244 | 37 | 126/145 | Ф165 | ≈250 | ||||
SLP800L | 250 | 320 | ||||||||
SLP1600 | 165 | 293 | 37 | 64 | Ф165 | ≈250 | ||||
SLP1600L | 250 | 320 |
Notes: As to the fraction data, the numerator is under 6000N.m (Including 6000N.m) specification product; the denominator is 8000N.m specification product.
The basic electric controlling principle and related direction
1. The valve indicated in this diagram is located on the middle position.
2. The components in the dash dot line of this diagram are inside the electric actuator.
Terminal connection comparison table
Terminals | U | V | W | E | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
NO.of the | U | V | W | E | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
15 | KH | Heat relay |
14 | RP1 | Position potentiometer |
13 | STO STC | Torque switch |
12 | SL1 SL2 | Position limit switch |
11 | RH | Heater resistance |
10 | HR HG HY | Indicating lamp |
9 | SS SO SC | Remote controlling button |
8 | T | Transformer |
7 | R | Resistance |
6 | Idc | Position indicating meter |
5 | QC | Power supply switch |
4 | RP2 | Modulating potentiometer |
3 | FU | Fuse |
2 | KO KC | Alternative current contactor |
1 | M | Three- phase asynchronous motor |
No. | Code | Descriptions |
Directions
The above diagram shows the basic electric controlling principle of the series SLP electric actuators, it can perform the control for electric valve in the ordinary conditions. In the actual applications, the electric controlling principle has lots of requirements. For example, require to add controlling contacts of travel and torque and passive terminals, require local controlling switch and local/ remote change-over switch, require indicating lamp of local valve position, require the precise potentiometer and valve position transmitter (VOT) and require the function that the electric actuator can receive 4~20mA signal etc. So, the users should direct the requirements when ordering. Our company will provide the principle brochure consisted of all the electric controlling functions for users selecting.