IP68 Electric Actuator

Main Technical Parameters 1.Intrinsic error: ±1% 2.Return difference: 1% 3.Dead zone: 0.5% ~ 10% adjustable 4.Damping force characteristic: dead-beat 5.Protection level: IP67(IP68 optional) 6.Environment temperature: -25℃ ~ +70℃ 7.Relative Humidity: <95%(without condensation) 8.Power supply:...

Main Technical Parameters

1.Intrinsic error: ±1%

2.Return difference: 1%

3.Dead zone: 0.5% ~ 10% adjustable

4.Damping force characteristic: dead-beat

5.Protection level: IP67(IP68 optional)

6.Environment temperature: -25℃ ~ +70℃ 

7.Relative Humidity: <95%(without condensation)

8.Power supply: 380Va.c(340V~440V), 50Hz/60Hz 3PH


The running performance of the actuator can be guaranteed in the case of the 

voltage error of ±10% and the frequency error of ±5 Hz. The actuator can 

start normally in the case of the maximum voltage drop of 15%, and can run 

as the normal speed.

Model

Revolving Speed

(rpm)

Torque

(Nm)

Voltage (V)

Phase (Ph)

Frequency

(Hz)

Power (kW)

Rated Current (A)

Duty

Weight

 (kg)

FRYQ18

18

136

380

3

50

0.37

3.3

S2(15min)

30

24

108

380

3

50

0.37

3.3

S2(15min)

30

36

72

380

3

50

0.37

3.3

S2(15min)

30

48

54

380

3

50

0.37

3.3

S2(15min)

30

FRYQ25

18

400

380

3

50

1.1

5.8

S2(15min)

46

24

400

380

3

50

1.1

5.8

S2(15min)

46

36

298

380

3

50

1.1

5.8

S2(15min)

46

48

244

380

3

50

1.1

5.8

S2(15min)

46

FRYQ35

18

610

380

3

50

1.5

9.5

S2(15min)

69

24

610

380

3

50

1.5

9.5

S2(15min)

69

36

542

380

3

50

1.5

9.5

S2(15min)

69

48

474

380

3

50

1.5

9.5

S2(15min)

69

FRYQ40

18

1020

380

3

50

2.2

14.2

S2(15min)

190

24

1020

380

3

50

2.2

14.2

S2(15min)

190

36

845

380

3

50

2.2

14.2

S2(15min)

190

48

680

380

3

50

2.2

14.2

S2(15min)

190

FRYQ70

18

1490

380

3

50

3

18.2

S2(15min)

200

24

1490

380

3

50

3

18.2

S2(15min)

200

36

1290

380

3

50

3

18.2

S2(15min)

200

48

1020

380

3

50

3

18.2

S2(15min)

200

FRYQ90

18

2030

380

3

50

5.5

32

S2(15min)

200

24

2030

380

3

50

5.5

32

S2(15min)

200

36

1700

380

3

50

5.5

32

S2(15min)

200

48

1355

380

3

50

7.5

32

S2(15min)

200

FRYQ95

18

3000

380

3

50

7.5

42

S2(15min)

200

24

3000

380

3

50

7.5

42

S2(15min)

200


Optional Function

Hart Communication Protocol

HART communication uses a half-duplex communication method, which is characterized by the realization of digital signal communication on the existing analog signal transmission line, which is a transitional product during the transition from analog system to digital system, so it has a strong The

market competitiveness has developed rapidly. HART stipulates a series of commands, which work according to the command mode. 

IQ25_06

Profibus Communication Protocol

PROFIBUS is an international, open field bus standard that does not depend on equipment manufacturers. The transmission speed of PROFIBUS can be selected in the range of 9.6kbaud ~ 12Mbaud and when the bus system is started, all devices connected to the bus should be set to the 

same speed. It is widely used in manufacturing automation, process industrial automation and building, transportation and other fields of automation. PROFIBUS is a field bus technology used for factory automation workshop-level monitoring and field device layer data communication and control. 

IQ25_09


Modbus Communication Protocol

Modbus is a serial communication protocol published by Modicon (now Schneider Electric) in 1979 for communication using programmable logic controllers (PLCs). Modbus has become the industry standard for industrial communication protocols (De facto) and is now the usual connection between industrial electronic devices.

IQ25_12

Bluetooth Communication

  1. Visualization

  2. Debugging convenient

  3. Operation and monitoring functions 

  4. Diagnostic function

  5. Download,save,upload all the information

    IQ25_15

Protection Level---IP68

IP is the abbreviation of Ingress Protection. The IP rating is the protection level against foreign objects 

in the electrical equipment enclosure. The source is  the International Electrotechnical Commission's 

standard IEC 60529, which was also adopted as the US national standard in 2004.

imageimage

The relevant test basis in China is GB 4208-2008/IEC 60529-2001 "Shell protection grade (IP code)" 

standard requirements, the conformity assessment test for the enclosure protection grade of various 

products; the highest detection grade IP68. Regular product inspection levels include IP23, IP44, IP54, 

IP55, IP65, IP66, IP67, IP68.

The purpose of the test criteria is as follows:

Specify the degree of enclosure protection specified by the electrical equipment load;

Prevent the human body from accessing dangerous parts inside the casing;

Prevent solid foreign matter from entering the equipment inside the casing;

Prevents harmful effects on equipment due to water entering the enclosure.

 IQ25_18

Can be equipped with valves

IQ25_20

Previous: Modbus RTU TCP Motorized Actuator

Next: No Information