Main Technical Parameters
1.Intrinsic error: ±1%
2.Return difference: 1%
3.Dead zone: 0.5% ~ 10% adjustable
4.Damping force characteristic: dead-beat
5.Protection level: IP67(IP68 optional)
6.Environment temperature: -25℃ ~ +70℃
7.Relative Humidity: <95%(without condensation)
8.Power supply: 380Va.c(340V~440V), 50Hz/60Hz 3PH
The running performance of the actuator can be guaranteed in the case of the
voltage error of ±10% and the frequency error of ±5 Hz. The actuator can
start normally in the case of the maximum voltage drop of 15%, and can run
as the normal speed.
Model | Revolving Speed (rpm) | Torque (Nm) | Voltage (V) | Phase (Ph) | Frequency (Hz) | Power (kW) | Rated Current (A) | Duty | Weight (kg) |
FRYQ18 | 18 | 136 | 380 | 3 | 50 | 0.37 | 3.3 | S2(15min) | 30 |
24 | 108 | 380 | 3 | 50 | 0.37 | 3.3 | S2(15min) | 30 | |
36 | 72 | 380 | 3 | 50 | 0.37 | 3.3 | S2(15min) | 30 | |
48 | 54 | 380 | 3 | 50 | 0.37 | 3.3 | S2(15min) | 30 | |
FRYQ25 | 18 | 400 | 380 | 3 | 50 | 1.1 | 5.8 | S2(15min) | 46 |
24 | 400 | 380 | 3 | 50 | 1.1 | 5.8 | S2(15min) | 46 | |
36 | 298 | 380 | 3 | 50 | 1.1 | 5.8 | S2(15min) | 46 | |
48 | 244 | 380 | 3 | 50 | 1.1 | 5.8 | S2(15min) | 46 | |
FRYQ35 | 18 | 610 | 380 | 3 | 50 | 1.5 | 9.5 | S2(15min) | 69 |
24 | 610 | 380 | 3 | 50 | 1.5 | 9.5 | S2(15min) | 69 | |
36 | 542 | 380 | 3 | 50 | 1.5 | 9.5 | S2(15min) | 69 | |
48 | 474 | 380 | 3 | 50 | 1.5 | 9.5 | S2(15min) | 69 | |
FRYQ40 | 18 | 1020 | 380 | 3 | 50 | 2.2 | 14.2 | S2(15min) | 190 |
24 | 1020 | 380 | 3 | 50 | 2.2 | 14.2 | S2(15min) | 190 | |
36 | 845 | 380 | 3 | 50 | 2.2 | 14.2 | S2(15min) | 190 | |
48 | 680 | 380 | 3 | 50 | 2.2 | 14.2 | S2(15min) | 190 | |
FRYQ70 | 18 | 1490 | 380 | 3 | 50 | 3 | 18.2 | S2(15min) | 200 |
24 | 1490 | 380 | 3 | 50 | 3 | 18.2 | S2(15min) | 200 | |
36 | 1290 | 380 | 3 | 50 | 3 | 18.2 | S2(15min) | 200 | |
48 | 1020 | 380 | 3 | 50 | 3 | 18.2 | S2(15min) | 200 | |
FRYQ90 | 18 | 2030 | 380 | 3 | 50 | 5.5 | 32 | S2(15min) | 200 |
24 | 2030 | 380 | 3 | 50 | 5.5 | 32 | S2(15min) | 200 | |
36 | 1700 | 380 | 3 | 50 | 5.5 | 32 | S2(15min) | 200 | |
48 | 1355 | 380 | 3 | 50 | 7.5 | 32 | S2(15min) | 200 | |
FRYQ95 | 18 | 3000 | 380 | 3 | 50 | 7.5 | 42 | S2(15min) | 200 |
24 | 3000 | 380 | 3 | 50 | 7.5 | 42 | S2(15min) | 200 |
Optional Function
Hart Communication Protocol
HART communication uses a half-duplex communication method, which is characterized by the realization of digital signal communication on the existing analog signal transmission line, which is a transitional product during the transition from analog system to digital system, so it has a strong The
market competitiveness has developed rapidly. HART stipulates a series of commands, which work according to the command mode.
Profibus Communication Protocol
PROFIBUS is an international, open field bus standard that does not depend on equipment manufacturers. The transmission speed of PROFIBUS can be selected in the range of 9.6kbaud ~ 12Mbaud and when the bus system is started, all devices connected to the bus should be set to the
same speed. It is widely used in manufacturing automation, process industrial automation and building, transportation and other fields of automation. PROFIBUS is a field bus technology used for factory automation workshop-level monitoring and field device layer data communication and control.
Modbus Communication Protocol
Modbus is a serial communication protocol published by Modicon (now Schneider Electric) in 1979 for communication using programmable logic controllers (PLCs). Modbus has become the industry standard for industrial communication protocols (De facto) and is now the usual connection between industrial electronic devices.
Bluetooth Communication
Visualization
Debugging convenient
Operation and monitoring functions
Diagnostic function
Download,save,upload all the information
Protection Level---IP68
IP is the abbreviation of Ingress Protection. The IP rating is the protection level against foreign objects
in the electrical equipment enclosure. The source is the International Electrotechnical Commission's
standard IEC 60529, which was also adopted as the US national standard in 2004.
The relevant test basis in China is GB 4208-2008/IEC 60529-2001 "Shell protection grade (IP code)"
standard requirements, the conformity assessment test for the enclosure protection grade of various
products; the highest detection grade IP68. Regular product inspection levels include IP23, IP44, IP54,
IP55, IP65, IP66, IP67, IP68.
The purpose of the test criteria is as follows:
Specify the degree of enclosure protection specified by the electrical equipment load;
Prevent the human body from accessing dangerous parts inside the casing;
Prevent solid foreign matter from entering the equipment inside the casing;
Prevents harmful effects on equipment due to water entering the enclosure.
Can be equipped with valves